About 138,000 results
Open links in new tab
  1. Best of a Bad S-Trap Situation? - Love Plumbing & Remodel

    Dec 8, 2019 · An AAV can be contaminated if waste gets pushed into it, so it's advantageous to get it as high as possible after the p-trap so a backup is less likely to damage it. FWIW, they …

  2. Is there any way to test an Air Admittance Vent?

    Nov 13, 2020 · FWIW, It seems as if the AAV are very effective at sealing under pressure, which is what the tests I just made using the tips above seemed to indicate, but the function I really …

  3. Washing Machine + Slop Sink + AAV - Love Plumbing & Remodel

    Apr 5, 2012 · The AAV is a one way valve letting air in to prevent siphonage, which BOTH traps need and your AAV will provide. The positive pressure situation occurs if the discharge is …

  4. Kitchen S trap to P Trap and AAV set up help.

    May 22, 2025 · Hi, My sink has been plumbed with an S Trap since I remodeled In 2010, I get gurgling when dishwasher runs and sometimes sink drains slow ( speeds up if I manually open …

  5. Should I add an AAV to my single bowl kitchen sink?

    Dec 29, 2015 · If I need an AAV, I could use the "unused" 1-1/2 connection on the left side of the sani-tee to add the AAV. If this is a good idea, I would add enough pipe to get the AAV to the …

  6. 2 Air Admittance Valves on double sink, IPC 2009

    Jun 25, 2010 · Hey All, My local inspector allowed me to use AAVs on my kitchen double sink, as there was no good way to hard vent it. He said that a double wye with an AAV off the top was …

  7. Any disadvantages to using an AAV - Love Plumbing & Remodel

    Dec 8, 2022 · An AAV only works with negative pressure, no positive pressures. A vent through the roof does both. In fact a vent through the roof is needed somewhere in the system for an …

  8. Distance to air gap drain. - Love Plumbing & Remodel

    Jan 24, 2025 · Yes for the IPC, although that requires you to get the exact slope of 1/4" per foot. Slope it more, you reduce the maximum horizontal. No for the UPC, as it further imposes a …

  9. Laundry room drains - washer and sink on same drain with AAV

    Nov 20, 2022 · The bathroom downsteam will be vented temporarily with an aav, and then when renovations are continued next year on the upstairs bathroom, venting will be tied into the …

  10. Basement Bathroom Wet Vent + AAV - Love Plumbing & Remodel

    Mar 18, 2024 · DIY plumbing a basement bathroom in Michigan (IPC) and am wondering about venting. Only real access to existing stack is a 3" line that carries waste from other bathrooms …