Jul 3, 2017 · I recently had an HVAC contractor install several ducted Mitsubishi minisplit units in our home (SEZ-KD09 & SEZ-KD12). The contractor did all of the work with the exception the condensate …
How best to manage minisplit condensate drainage
Dec 26, 2019 · I have received shipment of the 3-zone ductless minisplit system that I plan to install in my small, block-construction Tampa house, to replace the central heat pump that I decided to stop …
Which condensate pump to use? - HVAC-Talk
Jun 16, 2018 · I have installed little giant EC-OP series mini split condensate removal pumps 4 years back. And as per my experiences this is the best pump I ever used. It has Low weight, Compact size …
No condensate from Mitsu mini split - HVAC-Talk
Jul 3, 2009 · The unit is cooling fine. The stat is set at 74. In case anyone is interested, this is a room above the garage that doesn't have an air return to the ducted system with insufficient ducting to be …
condensate pump for mini split - HVAC-Talk
Apr 28, 2022 · Had to replace a mini split condensate pump, making a lot of noise and the guy thats in the next room to servers was complaining. so this was a mini 2 piece pump and i replaced it wth a a …
Condensate drain line installation for minisplit head units when the ...
Aug 20, 2022 · I’m looking for tips and tricks for condensate drain line installation for head units when the refrigerant lines are run thru the attic above the head units. The options I’m […]
Mini Split Condensate Pump DESPERATE need of advice.
Aug 20, 2015 · This is a NEW installation of a Daikin 2 ton Mini split and pump: Purchased 4 (four different ) Sauermann Si-30 condensate pumps all have failed after 3-4 days of use.
Loud Minisplit Pump - GreenBuildingAdvisor
Jul 21, 2020 · All condensate pumps make noise. None will ever be quiet enough if the mini split is in your bedroom. If you have a thermostat, you can program the minisplit to turn off when you go to …
Quiet condensate pump for mini split - HVAC-Talk
Oct 3, 2016 · I have a Fujitsu mini split system. One of the units is below ground level, so it has a condensate pump. It works fine but is annoyingly loud when it flips on. Can anyone rec a quiet …
How to Prevent Condensate Leaks from Ductless Heat Pumps
Jul 7, 2021 · Building Science How to Prevent Condensate Leaks from Ductless Heat Pumps Understanding the system’s operation and maintenance requirements can head off future problems